Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Journal of Practical Medicine ; (24): 934-937, 2014.
Article in Chinese | WPRIM | ID: wpr-446464

ABSTRACT

Objective To study the changes of posterior corneal elevation with one-year follow-up by using Allegro Oculyzer anterior segment diagnostic system in patients who had undergone laser in situ keratomileusis with femtosecond laser (FS-LASIK) for myopia. Methods Ninety eyes of forty-five patients who had undergone FS-LASIK for myopia were included in our study . The spherical equivalent of ametropia was-10.63D to -1.63D. The preoperative and postoperative corneal tomography (including 1, 3, 6 and 12 month after operation ) were collected by Allegro Oculyzer in the posterior corneal elevation and the thickness at central corneal thinnest point of each eye were measured , and the differences of the posterior corneal elevation were calculated. The data were analyzed with ANOVA and Pearson correlation analysis. Results There were no statistically significant differences in the changes of posterior corneal elevation from the preoperative time to the any postoperative follow-up time (F = 1.50, P > 0.05). There were no statistically significant changes of the posterior corneal elevation from the 1st month to 12th month postoperatively (F = 1.47, P > 0.05). There were statistically significant differences in the changes of thickness at central corneal thinnest point from the preoperative to the 12th month postoperative (F = 369.10, P 0.05). Conclusion After strictly followed surgical indications in FS-LASIK, the posterior corneal elevation can keep good stability and has no significant change. Thickness of central cornea thinnest point increases gradually and tends to stablity at the 3th months after surgery.

2.
Chinese Journal of Nosocomiology ; (24)2009.
Article in Chinese | WPRIM | ID: wpr-595799

ABSTRACT

OBJECTIVE To study the analytic method for assaying of glutaral concentration by enzyme-labeled device at one time.METHODS Controlled solution of glutaral and sample solution were taken out and kept until the room temperature.Optical density value was detected at 450 nm.Content of sample was calculated by comparison with the known concentration of glutaral.RESULTS In the range of 0.75-2.50%,concentration of glutaral had linear relationship with the optical density value.Reproductive test:relative average error was within 2%,RSD≤2.51%;interference test:oxidation-resistant-sodium nitrite could make the result negative error.0.1% Sodium nitrite could make the test result decrease by 1.5% relatively.CONCLUSIONS The method is simple,fast and convenient,with accuracy which has met the requirement of hospital infection monitoring and acceptable interfering range made by additives,which is highly practical.

SELECTION OF CITATIONS
SEARCH DETAIL